Configure the Devices Connected to the RVON-C Card
See the device user manual for specific configuration instructions
Setting up a Serial Pass-Through Connection or Serial Connection
If you plan to pass data using either a Serial Pass-Through or Serial Connection you will need to set the DIP switches and
jumpers to reflect which connection you will want to use.
NOTE: When making adjustments to the DIP switches and jumpers, you will need to take the front card out of the
Cronus.
To use the Serial Pass-Through, do the following:
1. Set DIP Switch 6 to the OPEN position.
2. Set the serial protocol, either RS232 or RS485:
For RS232, jumper pins 2 & 3 of J10, J11, and J12
For RS485, jumper pins 1 & 2 of J10, J11, and J12
3. Once you have set the correct configurations, replace the RVON-C into Cronus and hook the DB-9 connector to the
RVON-C backcard.
To use the Serial connection, do the following:
1. Set DIP Switch 6 to the CLOSED position.
2. Set the serial protocol, either RS232 or RS485:
For RS232, jumper pins 2 & 3 of J10, J11, and J12
For RS485, jumper pins 1 & 2 of J10, J11, and J12
3. Once you have set the correct configuration, replace the RVON-C into Cronus and hook the DB-9 connector to the
RVON-C backcard.
4. Use Table 4, “Serial Command Table,” on page 73 to configure you RVON-C card.