48 Chapter 10 Pinout Reference
EIA 232 Information
RS 232 Flow Control Primer
RS
RS-232 Flow Control Primer
Hardware flow control uses pins RTS and CTS to gate flow back and forth between two connected
serial devices. The DTE device uses RTS to start and stop flow from the DCE device, and the DCE
device uses CTS to gate flow from the DTE device. This method is popular for higher speed
connections where flow control reaction time is more critical. It's also popular where the data stream is
such that embedded flow control characters can not be tolerated by the protocol running on the link.
The cost is that you have to run two more wires in the cable.
Software flow control uses special START (XON) and STOP (XOFF) characters embedded in the
data stream to gate flow. In other words, the receiving device would send a STOP character (typically a
control-s) to the sending device to halt flow. It would then later send a START character (typically a
control-q) to resume flow. This method of flow control is more popular for slower links whose protocol
can support embedded flow control characters. It's popular because it only requires that you run 3 wires
for the link to function: Receive (RxD), Transmit (TxD), and Ground (GND).