SECTION
2:
INSTALLATION
I
2.1 MECHANICAL INSTALLATION
The Model SAP1626 mounts in a standard 19 inch
rack, in a space two rack units high (3.5 inches). The
BOP220 should be mounted in the same rack as the
SAP1626 behind the SAP1626.
2.2
ELECTRICAL INSTALLATION
2.2.1 ELECTRICAL INSTALLATION, POWER
The SAP1626 distributes DC power and signals but
no power
is
required to operate the SAP1626 itself
and there are no power connections.
2.2.2 ELECTRICAL INSTALLATION, SIGNALS
The electrical installation of the SAP1626 requires
one to four four-conductor shielded cables, two f@-
conductor cables, and optionally, a twenty five-con-
ductor cable, and microphone cables.
(3
The one to four four-conductor cables
are
used to
connect one to four TW* Power Supplies, respec-
tively, to the SAP1626 "INTERCOM
CHANNEL
INTERCONNECT" inputs.
The two fifty-conductor cables connect the SAP1626
"EXTERNAL USER STATIONS" "OUTPUTS" to
the BOP220 "CONNECTIONS TO SAP1626, J121,
5122".
The twenty five-conductor cable connects the
SAP1626 "INTERCONNECTION TO VIE306
MODEL
306"
outputs to the VIE306, CIF612, or
di-
rectly to the cameras or optionally, user stations.
The microphone cable connects program sources to
the SAP1626. The SAP1626 program input
impedance
is
800
ohms. Typical levels to feed into the
program input ranges from OdBm to -lOdBm.
Figure 2-1 shows interconnection of a SAP162.6,
BOP220,l to
4
TW
Power Supplies**, and a VIE306.
Figure 2-2 shows the
wiring
of a four-conductor
cable**.
Fie 2-3 shows the
wiring
of a twenty-five-
conductor cable.
Fie
2-4
shows
wiring
of a program Input cable.
Figure 2-5 shows how to wire a
TW
User Station ca-
ble to plug into one of the twenty BOP2U) outputs.
Figure 2-6 shows the interconnection of the SAP1626
to a TW/802 Series type intercom system.
Since the SAP1626 has no current limiters, PS50 and
PS60 power supplies may shorten the life of the
thumbwheel switches, but current limiters may be
added to the SAP1626. See Appendix B for a triple
current limiter, circuit assembly. To protect all 12 ac-
tive buses of the SAP1626 requires 4 assemblies.
(Continued, overleaf)
*
TW
here means the RTS Systems, Two Wire Inter-
com system which combines DC power and unbal-
anced intercom signals. One channel requires two
wires, two channels, three wires, et cetera.
**
If the TW Power Supply is
a
PS30 made before
mid 1983, see Appendix A for instructions on how to
connect the PS30 supplies to the SAP1626
Alternatively, program inputs
can
used to monitor op-
tional channels
13,
14, 15. (via a 10 kilohm bridging
amplifier)
Page 2-1