  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 38
SECTION
B:
APPENDIX
B
B2
Detailed Information
I
B.l
General Information and Definitions
Normally the SAP1626 serves the dual purpose of sig-
nal and
DC
power distribution. In general, the
SAP1626 connects between the system channels or
buses and
TW
User Stations or strings of
TW
User
Stations (normally to the
TW
User Stations through
the BOP220). The system channels or buses are usu-
ally established by
TW
Power Supplies. Often these
buses are also connected to an
800
series balanced
intercom system through a System Interconnect (e.g.
Models 862,860).
A "wet" channel contains 32 volts
DC
and two-way
intercom audio.
A
"dry"
channel contains two-way intercom audio
only.
A
TW
User Station must be connected so that its
channel
1
is connected to a "wet" channel; its channel
2 may be connected to either
a
"wet" or "dry" channel.
(Exception:
Local
powered
TW
User Stations
can
be
F3
arbitrarily connected to wet or
dry
channels).
The top row of switches on a SAP1626 connect to the
channel one inputs of
TW
User Stations and should
always be dialed to a "wet" channel. (Exception: If
all
stations are local powered, dial up
can
be arbitrary).
The bottom row of switches
can
be arbitrarily dialed
to any channel. Dialing to channel zero connects the
TW
User Station/Stations' channel two connection to
ground (dead channel).
The SAP1626 Power Supply Inputs
can
be
connected
to one, two, three, or four three channel power sup-
plies to get three, six, nine, or twelve "wet" channels,
respectively.
On the SAP1626, Channels 13,
14,
and 15 are always
dry, and, in general, the top row of switches should
not be left on these channels, because an unpowered
TW
User Station
could
absorb some of the Intercom
or Program Audio that may appear on these channels.
Because the SAP1626 has no current limiters, the
PS50 and PS60 power supplies may shorten the life of
the thumbwheel switches. Current limiters may be
added to the PS50 and PS60 power supplies to
lengthen switch life.
Figure B-1 shows the connection of the triple current
limiter in the SAP1626.
The triple current limiter schematic diagram, SD1598,
is on page 7-17,
in
the next section.
The triple current limiter assembly diagram, AS1601,
is on page 7-19,
in
the next section.
Page B-1