SECTION
3:
OPERATING INSTRUCTIONS
3.1 FRONT
PANEL
DESCRIPTION
REF
NAME DESCRlPTION
1
CAMERAS
r
CH
11
2 CAMERAS
[CH
21
Thumbwheel switches. Select first channel on
cameras
1
thru
6.
Thumbwheel switches. Select second channel on
cameras
1
thru
6.
3
EXTERNAL USER STATIONS Thumbwheel switches. Select first channel on
[CH
11
user stations connected to the
BOP2U).
Station numbers on
the
BOP2U)
correspond directly to EXTERNAL USER
STATIONS numbers on the SAP1626 front panel.
4
EXTERNAL USER STATIONS Thumbwheel switches. Select second channel on
[CH
21
user stations connected to the
BOP2U).
3.2
OPERATION
To select the channels that camera user stations
will
talk and listen on, turn CAMERAS thumbwheel
switches to the desired channels. The upper
thumbwheel selects channel
1
on camera intercom.
The lower thumbwheel switch selects channel 2 on
the camera intercom. Unless the camera user station
is
local
powered
the channel
1
thumbwheel must
be
set to a powered channel, i.e. channels 1-12. Channel
2 may be set to any channel regardless of power,
unless the user station has been modified to accept
power from
a
channel
2
connection.. If a
VIE306
is
used, channel 2 is the isolated "isoed" channel. Thus
the lower row of thumbwheels
will
select the channel
that is interupted by the
VIE306.
To select the channels that the external (non-
camera) user stations
will
talk and listen on, turn the
desired EXTERNAL
USER
STATIONS thumbwheel
to the desired channel. EXTERNAL USER
STATIONS numbers correspond directly to the
numbers on the
BOP220
Connector Translation
panel. Unless the external user station is local
powered, channel
1
must be set to a powered
channel, i.e. channels 1-12.
'
Because of electrical current limitations, a maximum
of
30
headset user stations
can
be assigned to the
same powered channel. This only applies to channel
1
of the user stations (upper row of thumbwheels)
and
is because power for the user stations is derived
from channel
1
(see Figure 4-1). More than one user
station
can
be connected to each SAP1626 output so
it
is
possible to exceed this limit. If stations with
speakers or
call
lights are used the maximum number
is
less. For exact numbers see the relevant Power
Supply Technical Manual.