CAMERA CONNECTIONS
The front panel
thumbwheel switches tie the camera outputs to one
of 15 buses.and The camera thumbwheel switch out-
puts are available on a rear panel 25-pin female "D"
connector.
An
optional Camera Iso Electronics,
Model VIE306,
can
be
connected the
25
pin
"D"
con-
nector.
Note that the lower row of camera thumbwheel
switches, labled [CH 21, select the channel that
is
to
be isolated by the VIEW.
Thumbwheel switches S1-S12 select the channels for
cameras 1-6. Odd numbered switches are the upper
row and select the camera's intercom channel
1.
Even numbered switches are lower row and select the
camera's intercom channel 2.
Output from these first 12 switches connects to rear-
panel D connector J8.
4.2
PROGRAM CHANNEL DESCRIPTION
(See SD3871 in Section
7)
The three program channels have identical circuitry.
Program
1
will
be
used as an example. Program
1
enters through rear-panel XLR-3-31 connector, J105.
Capacitors C1 and
C2
prevent direct current from
damaging the transformer, TI,
if
a cable carrying DC
is accidently connected to the program inputs.
The transformer,
TI, converts the
800
ohm balanced
input to a
200
ohm unbalanced line. The resistor, R1,
establishes the
200
ohms. The
200
ohm unbalanced
line
can
also serve as a "dry" RTS Systems
TW
bus
43
BOP220 DESCRIPTION
(See SD
4689,
Section
7)
Two-wire intercom audio plus 32 volts DC from the
SAP1626 connects to the BOP220 at 5121 and 5122
male 50-pin micro-ribbon connectors.
The
micrarib-
bon connectors are wired to the 20 XLR-3-32 type
male output connectors on the BOP220.
A
pair of
intercom channels
appear
on each XLR-3-32. On
each XLR-3-32, pin
1
is
common, pin 2
is
a channel
or bus selected by the upper row of switches on the
SAP1626, and
pin
3
is
a channel selected by the bot-
tom row of switches on the SAP1626, The
"EXTERNAL OUTPUT" number of the XLR-3-32
connectors corresponds to the column numbers on
the SAP1626. Thirty two volts DC may appear on
an
XLR-3-32, pins 2 and 3, referenced pin
1.
To operate
TW
User Stations, pin 2 must have
t
18 to +32 volts
DC on it with reference to pin
1
(common). The ex-
ception to this rule are
TW
User Stations with
"Local
Power Option", or
TW
or other stations operating in
the balanced mode, including Series
800.
Capacitor
C7
protects the transformer from direct
current from the RTS line.
Page 4-2
Comentarios a estos manuales