SECTION
5:
MAINTENANCE
5.1
INTRODUCTION
This section provides service information for normal
maintenance, factory performance tests and trouble-
shooting.
53 SERVICE INFORMATION
The Model SAP1626 is warranted for a period of one
year from the purchase date. The warranty and re-
turn instructions are in the front of this manual.
53 GENERAL MAINTENANCE
5.4 PERFORMANCE CHECK
EQUIPMENT NEEDED
Sine wave
oscillator
Oscilloscope,
1
MHz minimum bandwidth
Input cable
Small blade screwdriver
RTS
"IW"
power supply (PS30 or PS31)
Voltmeter to measure 35 volts DC
And for parts replacement:
Temperature controlled soldering iron
Rosin core,
60140
composition, solder.
53.1
SAFETY CONSIDERATIONS
DO NOT USE SOLDER
PASTE!
These servicing instructions are for qualified person-
nel only. To avoid electric.shock, do not perform any
servicing other than that contained in the operating
instructions unless qualif~ed to do so.
Service and adjustments should be performed only by
qualified service personnel.
If fuses are used,
be
certain that only fuses with the
required current rating and of the specified
type
(normal blow, time delay, slo--blo, etc.) are used for
replacement. The use of repaired fuses and the
short--circuitkg of fuse holders is prohibited.
WARNING
The service information presented in this manual is
normally used with the protective covers removed
and power applied to the equipment. Energy avail-
able at many points may,
if
contacted, result in per-
sonal injury.
ACCESS To get inside the Model SAP1626, remove
the screws on the top and bottom covers. Slide
covers off.
533 CLEANING
Clean the outside of the Model SAP1626 with dena-
tured alcohol or a mild solution of detergent and
water. Clean the interior with dry, low pressure
air.
The circuit boards
can
be
cleaned with
1,1,1
trichloroethane or Freon TF.
Do not allow these or
any solvents to get into the pots or switches.
5.4.1
VISUAL
Inspect unit.
Check for damage or missing parts.
Check for broken or frayed wires.
Check that
all
connectors are fully seated.
Verify that capacitors have proper polarity.
5.43 TURN-ON
5.43.1 Start with the thumbwheel switches at
0.
Connect the
"TW"
power supply to the power supply
input (5111) on the SAP1626 as shown in Section
2.
If
more power supplies are available, they may
be
connected to the other inputs (5112, J113, 5114) on
the SAP1626, however the rest of this procedure as-
sumes that one power supply is used. Connect a
BOP220 as shown in Section 2.
5.423 (OPTIONAL-When triple current limiter is
installed). Power up the
"TW"
power supply and
measure the output of each section of the triple cur-
rent limiter board. Output
can
be measured at the
fuses of the triple current limiter Al. Output should
read
30
+2 volts DC.
5.423 Check voltage at the bus connecting pins 1-3
of the thumbwheel switches. Voltage should
be
30
+2
volts DC on both the upper and lower
-
thumbwheels.