RTS WM300 Especificaciones Pagina 51

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 67
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 50
Chapter 2 Specification of Communication port for CPU module
2 – 37
2.3.2 Dedicated port
The specifications in setting the serial communication port as a dedicated port is shown in the table 2.21.
In the dedicated port, a CPU program can be created or monitored from the programming device connected. Also, a
monitoring system which uses a monitor available on the market can be constructed. Moreover, a variety of
systems can be constructed by connecting a personal computer and creating software.
For setup and setting the connecting cables, please check beforehand whether it is used as the purpose.
Table 2.23 Specifications for a dedicated port
Item Specification
Transmission speed *1 4,800 bps9,600 bps19,200 bps38,400 bps57,600 bps
Interface *1 RS-232C RS-422 RS-485
Maximum cable length 15 m 500 m 500 m
Connection mode (Maximum
connected units)
1 : 1 1 : 1 / 1 : N (32 units) 1 : 1 / 1 : N (32 units)
Communication system Half duplex system
Synchronization system Start-stop synchronization system
Startup system One-side startup system using the host side command
Transmission system Serial transmission (Bit serial transmission)
Transmission code ASCII
Transmission code
configuration
2
0
2
1
2
6
P
Stop bit (1 bit)
Parity bit (1 bit) Start bit (1 bit)
Data (7 bits)
(Even-numbered parity)
Transmission code outgoing
sequence
out from the lowest bit in character units.
Error control Vertical parity check, Sum check, Overrun check, Framing check
Transmission unit Message unit (variable length)
Maximum message length 1,460 bytes (including control characters)
Control procedure *1 H-series dedicated procedure (High protocol)
Standard procedure 1 (Transmission control procedure 1),
Simple procedure (Transmission control procedure 2) *2
Connector used 8-pin modular connector (RJ-45 type)
*1 Communication speed, communication interface, and control procedure are set using a Control Editor.
It is set to 1:1 for the transmission control procedure 1, RS-232C, and 38,400 bps at shipment.
The setup becomes effective when the power supply turns on next.
*2 Transmission control procedure 2 is a simple communication protocol not support communication via CPU
link network.
Vista de pagina 50
1 2 ... 46 47 48 49 50 51 52 53 54 55 56 ... 66 67

Comentarios a estos manuales

Sin comentarios