Intercom Port Connections
16
TABLE 8. UIO-256 Relay Outputs Connector (J5)
Relay Output Numbers
a
PIN
NC Contact Common NO Contact
1/17/33/49 38 13 40
2/18/34/50 39 14 15
3/19/35/51 41 16 43
4/20/36/52 42 17 18
5/21/37/53 44 19 46
6/22/38/54 45 20 21
7/23/39/55 47 22 49
8/24/40/56 48 23 24
9/25/41/57 26 1 28
10/26/42/58 27 2 3
11/27/43/59 29 4 31
12/28/44/60 30 5 6
13/29/45/61 32 7 34
14/30/46/62 33 8 9
15/31/47/63 35 10 37
16/32/48/64 36 11 12
a. Dependent on UIO-256 DIP Switch SW1 Settings for Input/Output Range as summarized in Table 7.
The relay contacts are rated for 0.5A at 120 VAC; 1A at 24 VDC; 0.3A at 60 VDC
TABLE 9. UIO-256 Opto-Isolated Inputs Connectors (J7)
Relay Output Numbers
a
PIN Numbers
DC Control Input “-”
DC Control Input “+”
(50 to 30 VDC)
1/17/33/49 9 34
1/18/34/50 10 35
3/19/35/51 11 36
4/20/36/52 12 37
5/21/37/53 13 38
6/22/38/54 14 39
7/23/39/55 15 40
8/24/40/56 16 41
9/25/41/57 1 26
10/26/42/58 2 27
11/27/43/59 3 28
12/28/44/60 4 29
13/29/45/61 5 30
14/30/46/62 6 31
15/31/47/63 7 32
16/32/48/64 8 33