RVON-8 Default Setup
Every attempt is made to ensure the board is shipped from the factory containing the following:
All are “set rvon” commands
There are more parameters that the software will auto-configure if they have not been previously setup. The user can also set
these parameters, in which case the software would not modify but take them as they are.
activate
Must do an activate command to cause changes
to take effect.
show rvon Display current settings
show channel
[chan]
Display current settings
show emac Display current settings
VARIABLE ENVIRONMENT NAME DEFAULT
VA L U E
DESCRIPTION
ip_addr EMACA_IPADDR 192.168.0.1 IP Address for the RVON-8 Card
netmask EMACA_NETMASK 255.255.255.0 Network Mask for the RVON08 card
gateway EMACA_GW none Gateway IP Address for the RVON-8 Card
serial_ip RVON_SERIAL_IP none Pass-thru serial port IP Address for the RVON-8
Card
serial_baud RVON_SERIAL_ Baud 9600 Set the pass-thru serial port baud rate for the
RVON-8 Card
user RVON_USER telex RVON-8 user name for telnet access
password RVON_PASSWORD password RVON-8 password for telnet access (8-40
characters)
vad_threshold RVON_THRESHOLD_VAD adaptive VAD Threshold
TABLE 5. RVON-8 Command Table