7
DIP Switch 1 Closed: Configuration via AZedit is disabled
Open: (Default) Configuration via AZedit is enabled.
Description: Disables configuration changes via AZedit. AZedit will still be able to view the card
configuration and connection status. The configuration can still be changed via the serial
and Telnet connections.
DIP Switch 2 Closed: The RVON card holds the definitive configuration file.
Open: (Default) The Master Controller holds the definitive configuration file.
Description: Assigns where the configuration file for the RVON products is to be stored, either on the
Master Controller or the RVON card.
DIP Switch 3 Unused - Keep in Open position.
DIP Switch 4 Closed: When enabled, the card is prevented from resetting after 30 seconds of no
communications with the system controller.
Open: When disabled, the card resets after 30 seconds of no communication with the
system controller.
Description: Allows pass-through serial data to continue when the intercom is otherwise down (i.e.,
upgrades). Mainly used to keep trunking connections open when disruptions in
communications on the card occur.
DIP Switch 5 Closed: Resets the Telnet username and password to their default values:
User = telex
Password = password
Open: (Default) Uses current username and password
Description: Enables the user to reset the Telnet Username and Password.
DIP Switch 6 Closed: Enables a serial monitor on the backcard DB9 (J2).
Open: (Default) Enables a pass-through serial port via the backcard DB9 (J2)
Description: Selects DB9 (J2) serial configuration.
DIP Switch 7 Closed: Runs the Boot Download
Open: (Default) Runs the native flash program.
Description: Switches to the boot download flash program. This program is sent with the RVON-8 card
in case the native flash program becomes corrupt.
DIP Switch 8 DEBUG ONLY!
WARNING: DIP Switch 8 should always be left in the OFF position. It is reserved for
debugging and can have unintended consequences.